LET´S WORK TOGETHER.   Welcome to HAHN+KOLB France | For commercial customers only
PCE INSTRUMENTS

Brand: PCE INSTRUMENTS

Art.-no. 48603100

Manufacturer article no. PCE-COM 20

EAN 4250348716828


Individual prices for customers after login

You need more information or have not found your desired product?

Application

The conductivity measuring instrument for the electrical conductivity of non-ferrous metals such as aluminium or copper belongs to the NDT group of devices. The conductivity measuring instrument is used in non-destructive material testing. Using the eddy current measuring principle, which has been proven for this application, the electrical conductivity of metallic materials can be determined quickly and precisely.

Execution

  • Determination of metals and characterisation of alloys
  • Assessment of differences in strength in heat-treated or hardened materials
  • Authenticity testing of coin alloys
  • Checking of alloy inhomogeneities in critical components and material sorting
  • Menu languages: German, English, Chinese (simplified)
  • 14 mm diameter sensors
  • Measured value storage for up to 500 values
  • with USB interface

Delivery

with probe dia. 14 mm, calibration plate set, software, USB data cable, charging adapter, hexagon socket wrench, operating instructions, in case

Product information

Certificates/ Documents

 | 

 | 

Brand

PCE INSTRUMENTS

Main EAN Code

4250348716828

Manufacturer Part Number

PCE-COM 20

Type description

PCE-COM 20

Type of rechargeable battery/battery

Li-lon

Gross Weight

0.415 kg

Specifications
Measuring frequency60 kHz, sine wave
Conductivity measuring range0.51 % IACS to 112 % IACS
0.3 MS/m to 65 MS/m
Resistance 0.015388 to 3.33333 Ω•mm²/m
Resolution0.01 % IACS (at <51 % IACS)
0.1 % IACS (at 51 % IACS to 112 % IACS)
Measuring accuracy±0.5 % at +20 °C
±1 % in the range 0 to +40 °C
Lift-off compensationProbe head compensation 0.5 mm
Temperature measuring range0 to +50 °C
Temperature measuring accuracy±0.5 °C
Automatic compensationThe conductivity measurement result is automatically adjusted to the value at 20 °C
Operating conditions0 to +50 °C, 0 to 95 % relative humidity

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information
CAD data (available after login)

Certificates/ Documents

 | 

 | 

Technical information